[ANSYS, Inc. Logo] return to home search
next up previous contents index

3.2.4 Face Macros

The macros listed in Table  3.2.20- 3.2.23 can be used to return real face variables in SI units. They are identified by the F_ prefix. Note that these variables are available only in the pressure-based solver. In addition, quantities that are returned are available only if the corresponding physical model is active. For example, species mass fraction is available only if species transport has been enabled in the Species Model dialog box in ANSYS FLUENT. Definitions for these macros can be found in the referenced header files (e.g., mem.h).



Face Centroid ( F_CENTROID)


The macro listed in Table  3.2.20 can be used to obtain the real centroid of a face. F_CENTROID finds the coordinate position of the centroid of the face f and stores the coordinates in the x array. Note that the x array is always one-dimensional, but it can be x[2] or x[3] depending on whether you are using the 2D or 3D solver.


Table 3.2.20: Macro for Face Centroids Defined in metric.h
Macro Argument Types Outputs
F_CENTROID(x,f,t) real x[ND_ND], face_t f, Thread *t x (face centroid)

The ND_ND macro returns 2 or 3 in 2D and 3D cases, respectively, as defined in Section  3.4.2. Section  2.3.15 contains an example of F_CENTROID usage.



Face Area Vector ( F_AREA)


F_AREA can be used to return the real face area vector (or `face area normal') of a given face f in a face thread t. See Section  2.7.3 for an example UDF that utilizes F_AREA.


Table 3.2.21: Macro for Face Area Vector Defined in metric.h
Macro Argument Types Outputs
F_AREA(A,f,t) A[ND_ND], face_t f, Thread *t A (area vector)

By convention in ANSYS FLUENT, boundary face area normals always point out of the domain. ANSYS FLUENT determines the direction of the face area normals for interior faces by applying the right hand rule to the nodes on a face, in order of increasing node number. This is shown in Figure  3.2.1.

Figure 3.2.1: ANSYS FLUENT Determination of Face Area Normal Direction: 2D Face
figure

ANSYS FLUENT assigns adjacent cells to an interior face ( c0 and c1) according to the following convention: the cell out of which a face area normal is pointing is designated as cell C0, while the cell in to which a face area normal is pointing is cell c1 (Figure  3.2.1). In other words, face area normals always point from cell c0 to cell c1.



Flow Variable Macros for Boundary Faces


The macros listed in Table  3.2.22 access flow variables at a boundary face.


Ejma Standardpdf Fix Site

Crucial information on anchoring, guiding, and supporting systems to prevent premature failure.

While you may find "EJMA standard pdf" snippets online, relying on unofficial sources can be dangerous. The actual manual contains critical updates regarding:

Methods for calculating natural frequencies to avoid resonance. How to Access the Standards ejma standardpdf

Enhanced formulas for predicting how many cycles a bellows can survive.

Standardized methods for hydro-testing and non-destructive examination (NDE). Why You Need the Official EJMA Manual How to Access the Standards Enhanced formulas for

The Expansion Joint Manufacturers Association (EJMA) is an organization of leading manufacturers of metallic bellows expansion joints. They collaborate to establish and maintain a set of rigorous design rules and safety standards. The most current primary document is the , which provides the complex mathematical formulas needed to calculate bellows performance under various pressure and temperature conditions. Key Components of the EJMA Standards

You can buy the printed manual or a licensed digital copy at the official EJMA website . They collaborate to establish and maintain a set

The (Expansion Joint Manufacturers Association) are the globally recognized authority for the design and selection of metallic bellows expansion joints. Whether you are an engineer, a piping designer, or a procurement specialist, understanding the "EJMA Standard PDF" is crucial for ensuring the safety and longevity of piping systems. What are the EJMA Standards?


See Section  2.7.3 for an example UDF that utilizes some of these macros.



Flow Variable Macros at Interior and Boundary Faces


The macros listed in Table  3.2.23 access flow variables at interior faces and boundary faces.


Table 3.2.23: Macros for Interior and Boundary Face Flow Variables Defined in mem.h
Macro Argument Types Returns
F_P(f,t) face_t f, Thread *t, pressure
F_FLUX(f,t) face_t f, Thread *t mass flow rate through a face


F_FLUX can be used to return the real scalar mass flow rate through a given face f in a face thread t. The sign of F_FLUX that is computed by the ANSYS FLUENT solver is positive if the flow direction is the same as the face area normal direction (as determined by F_AREA - see Section  3.2.4), and is negative if the flow direction and the face area normal directions are opposite. In other words, the flux is positive if the flow is out of the domain, and is negative if the flow is in to the domain.

Note that the sign of the flux that is computed by the solver is opposite to that which is reported in the ANSYS FLUENT GUI (e.g., the Flux Reports dialog box).


next up previous contents index Previous: 3.2.3 Cell Macros
Up: 3.2 Data Access Macros
Next: 3.2.5 Connectivity Macros
Release 12.0 © ANSYS, Inc. 2009-01-14